Class A fire rated film, explained

Facilities managers and fire marshals ask us about fire rating on almost every commercial job. Here's what the rating means, why it matters in corridors and stairwells, and how we handle labeled fire doors.

The test

Interior finishes in commercial buildings are rated with ASTM E84, also published as UL 723. A sample about 24 feet long is mounted on the ceiling of a long tunnel and a gas flame is lit at one end. The lab measures how far and how fast the flame travels down the sample, and how much smoke comes off it.

Those two results become the flame spread index and the smoke developed index. Building codes sort finishes into three classes by flame spread, and require a smoke developed index of 450 or less for all three.

ClassFlame spread indexSmoke developed indexWhat it means
Class A0 to 25450 or lessSlowest flame spread. Meets the strictest interior finish requirements.
Class B26 to 75450 or lessAllowed in many rooms, but not always in exits.
Class C76 to 200450 or lessThe lowest class allowed for interior wall and ceiling finish.

Why it matters where you put it

The International Building Code sets the minimum class for interior wall and ceiling finish based on how the building is used and where the finish is. Exit stairways and exit passageways get the strictest limits, then corridors, then rooms. Sprinklers can relax some of those limits.

Because Class A is the strictest class, a Class A film can go in corridors and stairwells as well as rooms and lobbies. That's why we only spec Class A films for commercial projects.

The surface underneath counts. Manufacturers test their film applied to specific substrates, like gypsum board, wood, steel or MDF. We follow the manufacturer's substrate guidance so the rating holds on your project.

Labeled fire doors

Fire rated doors and frames carry a label, usually on the hinge edge of the door and on the frame. They're maintained under NFPA 80, and your local authority having jurisdiction, usually the fire marshal, decides what's acceptable in the field.

Here's how we handle them on every project:

  1. Find the labels

    We note every labeled door and frame at the walkthrough.

  2. Keep them visible

    Labels are never covered, painted around or removed.

  3. Same hardware

    The closer, latch and hinges that came off go back on. We don't swap or modify rated hardware.

  4. Class A film only

    And we hand you the product data for your fire marshal or facilities team.

This page is general information, not code advice. Your local fire marshal has the final say for your building.

Questions

Is all architectural film Class A?

No. Ratings vary by product and by what the film is tested on. The 3M DI-NOC and LX Hausys Benif films we install carry Class A ratings when applied to the substrates the manufacturer lists. We check that before we spec a film for your building.

Does wrapping a fire door void its rating?

Labeled fire doors fall under NFPA 80, and what's allowed in the field is up to your authority having jurisdiction, usually the local fire marshal. We keep labels exposed, keep the original hardware, use Class A film, and recommend you check with your fire marshal before a large fire door project. We'll provide the product data for that conversation.

Can you send documentation?

Yes. We provide the manufacturer's fire rating data for the specific films on your project, so your facilities team, architect or fire marshal can review them.

Need data sheets first?

Tell us what you're planning to refinish and we'll send the fire rating data for the films we'd use, before you commit to anything.